Vasundhara Performance Solutions is the authorised Hyderabad supplier for the HD Fire Protect monitor nozzle range — fixed water monitors, manual oscillating water monitors, remote-controlled / motorised oscillating water-foam monitors, foam-water combination monitors, jetty monitors for marine + offshore applications, and self-oscillating water monitors for tank-cooling applications. Flow capacity range from 750 lpm (200 gpm) to 7,500 lpm (2,000 gpm). UL Listed / FM Approved / TAC Approved / IS 8442 / IS 904 compliant. For refinery / petrochemical fixed-installation fire protection + LPG storage protection + jetty / port-handling applications. Pan-India dispatch from Secunderabad warehouse.
Request HD Fire Monitor Quote Call: +91-9912825442Complete coverage across the monitor nozzle product family — fixed, oscillating, manual, motorised + remote-controlled, water + foam variants.
Fixed-position water monitor with manual elevation + traverse control — wheel-operated for both axes. Flow capacity 750-2,500 lpm typical. Aluminium-bronze body. The cost-economic baseline for fixed-installation water monitor coverage. Standard for refinery + petrochemical protection where remote control isn't required.
Manual oscillating water monitor — auto-oscillates within preset limits driven by water-flow energy. Manual elevation + traverse limit setting; oscillation is automatic during operation. For tank-cooling water-spray applications + general process-plant fixed-installation coverage. Reduces operator-on-station requirement.
Motorised water monitor with electric / hydraulic remote control — operator at safe distance via remote panel. Elevation, traverse, oscillation, on/off all remotely controlled. For high-hazard applications where operator cannot be at-monitor — refinery / petrochemical / LPG / jetty installations. Premium pricing.
Combination water-foam monitor with switchable water-only or foam-water modes. Foam concentrate inducted at the monitor inlet via eductor + balanced-pressure proportioning. For fire-fighting foam application during refinery / petrochemical / aircraft / fuel-spill scenarios. Manual or motorised variants.
Jetty + marine monitor — corrosion-resistant body (bronze, monel, stainless steel options) for marine + offshore service. For port jetty fire protection, ship-to-shore fire-water transfer, offshore-platform monitor protection. Higher initial cost vs aluminium-bronze, justified by salt-water corrosion-resistance + extended service life.
High-capacity tank-cooling monitor (3,000-7,500 lpm) for above-ground petroleum storage tank cooling. Self-oscillating water-flow-driven action. Aluminium-bronze + stainless-steel internals. Typically rooftop-mounted on tank-shell-protection truss + dyke-area-mounted for surrounding-tank protection.
Standard property values across the range. TDS / MSDS / per-batch COA available on enquiry.
| Property | Test / Standard | Fixed 1500 lpm | Oscillating 2500 lpm | Motorised 2500 lpm | Foam-Water 2500 |
|---|---|---|---|---|---|
| Type | — | Fixed | Oscillating (auto) | Motorised (remote) | Combination foam-water |
| Flow Capacity (lpm @ 8 bar) | — | 1,500 | 2,500 | 2,500 | 2,500 |
| Body Material | — | Aluminium-bronze | Aluminium-bronze | Aluminium-bronze | Aluminium-bronze |
| Elevation Control | — | Wheel manual | Manual + auto-oscill | Electric remote | Manual / electric |
| Traverse Control | — | Wheel manual | Manual + auto-oscill | Electric remote | Manual / electric |
| Throw Distance (m, water) | IS 8442 | 60 | 75 | 75 | 70 |
| Approvals | UL / FM / TAC / IS 8442 | Yes (all four) | Yes (all four) | UL / FM / IS | UL / FM / NFPA 11 |
| Inlet Connection | — | 100 mm flanged | 100 mm flanged | 100 mm flanged | 100 mm flanged |
| Maximum Working Pressure (bar) | — | 12 | 12 | 12 | 12 |
Standards compliance: UL 162 / 1789 (monitor nozzles) · FM 5310 · TAC Approved · IS 8442 (water monitors) · IS 904 (foam monitors) · NFPA 24 (private fire service mains) · NFPA 15 (water-spray fixed systems) · NFPA 11 (foam systems) · OISD 116 / 117 (refinery / petrochemical)
Where HD Fire monitor nozzles ship from our Hyderabad warehouse — by hazard type and operator-station strategy.
Fixed + manual oscillating + motorised water monitors for refinery + petrochemical fixed-installation fire protection per NFPA 24 / OISD 116/117. Tank cooling, process-area protection, offsite-piperack protection. HPCL Visakhapatnam Refinery, ONGC, RCF petrochemical operations are common customers.
Motorised / remote-controlled water monitors + foam-water monitors for LPG bullet tanks + mounded LPG storage facilities. Operator-at-safe-distance requirement justifies the motorised premium. BPCL, HPCL, IOCL LPG bottling plants + storage terminals.
High-capacity tank-cooling monitors (3,000-7,500 lpm) self-oscillating, mounted on tank-shell-protection truss + dyke-area-mounted for surrounding-tank protection. Water-flow-driven oscillation eliminates operator-on-station requirement during active tank-cooling operations.
Jetty + marine corrosion-resistant monitors for port jetty fire protection + ship-to-shore fire-water transfer + offshore-platform applications. Bronze / monel / stainless-steel body justifies premium for salt-water service environment.
Foam-water combination monitors + motorised water-foam monitors for aircraft hangar + helicopter pad fire protection. Defence + civil-aviation airports + military airfields. Per NFPA 11 + military fire-protection standards.
Manual / motorised water monitors as supplemental protection layer for power-plant cable-trench + transformer-yard installations. Backup to fixed deluge sprinkler systems. NTPC, NHPC, state-utility GENCO + central-utility power-plant fire-protection scope.
For fire-system designers + EPC contractors specifying monitor nozzles — flow capacity selection + body-material choice (aluminium-bronze vs marine-grade) + manual vs motorised vs remote-controlled selection shape system performance + operator safety + insurance compliance.
Genuine HD Fire Protect equipment through manufacturer-authorised supply. UL / FM / TAC / IS approval documentation provided per shipment. Cartridge-traceability for warranty claims after service incidents.
Common-spec items stocked at Secunderabad warehouse for fast dispatch. Specialised configurations 1-2 weeks from HD Fire's Mumbai factory. Pan-India delivery to project sites under Vasundhara logistics control.
Hydraulic calculations, BOQ preparation, NFPA / IS compliance verification, design-document support for monitor nozzles integration into the broader fire-protection system. Free for projects where Vasundhara is the supply partner.
One PO for HD Fire monitor nozzles + companion equipment (hydrant valves, sprinklers, deluge valves, foam systems, monitors). Simplified procurement for EPC contractors and plant safety teams. See our HD Fire brand page.
Per-shipment test certificates, UL/FM/TAC type-test certificates, IS conformance reports, manufacturer authorisation letters. Suitable for fire department NOC submission, factory safety audit, MEP consultant submittals, and EPC project documentation.
GeM-registered seller — HD Fire equipment available under standing rate contract for PSU and Defence buyers. GFR-2017 compliant for deferred-payment supply. Documentation pack ready for streamlined Direct Procurement / L1 mode under GeM.
Standard packaging across the range. Bulk pricing on volumes >1,000 L.
| Pack Format | Volume | Typical Use Case |
|---|---|---|
| Pail (HDPE) | 20 L | Single-machine top-up, sample-and-trial orders |
| Drum | 50 L | Mid-duty maintenance stock |
| Barrel (steel) | 210 L | Plant maintenance stores standard |
| IBC Tote | 1000 L (1 MT) | Bulk supply for high-volume users |
| Bulk Tanker | 3,000-5,000 L+ | Direct-to-tank delivery, large plants |
Visit Our Office: H.No. 10-2-309, Flat No. 201, Sudha Vaishnavi Residency, Street No. 4, West Marredpally, Secunderabad, Telangana 500026 | View on Google Maps
Common questions from refinery, petrochemical, jetty and EPC contractor buyers sourcing HD Fire monitor nozzles through Vasundhara.
Fixed water monitor: manual wheel-operated elevation + traverse control. Operator must be at-monitor during operation. Cost-economic baseline. Manual oscillating monitor: auto-oscillates within preset limits driven by water-flow energy. Operator sets oscillation limits + activates flow, then can leave the monitor station. Reduces operator-on-station requirement. Motorised / remote-controlled monitor: full elevation + traverse + oscillation + on/off via remote-control panel. Operator at safe distance during operation — critical for refinery / LPG / petrochemical applications where heat radiation + explosion risk make at-monitor station hazardous.
Per NFPA 15 + OISD 116/117 + IS 904: design tank-cooling water flow rate is typically 10.2 lpm/m² of tank shell surface area to be protected. For a 30m diameter × 15m height tank: shell surface area ~1,400 m², total water flow 14,300 lpm. Distribute across multiple monitor nozzles (typically 4-6 nozzles per tank): 2,500-3,500 lpm per monitor capacity. Hydraulic calculation confirms total flow + pressure at each monitor. Vasundhara provides hydraulic calculation support for projects where we are the supply partner.
Yes. HD Fire's complete monitor nozzle range (fixed, oscillating, motorised, foam-water combination, jetty / marine) carries UL Listing + FM Approval + TAC Approval + IS 8442 (water monitors) / IS 904 (foam monitors) compliance. Per-shipment approval certificates provided. Suitable for refinery / petrochemical OISD compliance audit, factory-safety audit, MEP consultant submittals, EPC project documentation, insurance compliance.
Throw distance depends on inlet pressure + nozzle K-factor + water-spray pattern: typical 60-75 m for water monitors at 8-10 bar inlet pressure with straight-stream pattern, 30-45 m for fog / spray pattern. High-capacity tank-cooling monitors (5,000+ lpm at 12 bar) reach 80-100 m. Per IS 8442 testing standard. For specific installation applications, hydraulic calculation confirms achievable throw distance from the system operating pressure.
Yes — HD Fire foam-water combination monitors with eductor / balanced-pressure foam proportioning are compatible with all standard foam concentrate types: AFFF, AR-AFFF, Protein, Fluoroprotein. Foam concentrate is procured separately + sourced from foam concentrate manufacturers per NFPA 11 + IS 4308 specifications. Vasundhara can support foam concentrate sourcing through partner network.
Common-spec items (fixed water monitor 1,500 lpm, manual oscillating 2,500 lpm) — 4-6 weeks from HD Fire's Mumbai factory dispatch + 2-3 days from Secunderabad logistics. Motorised remote-controlled monitors + foam-water combination monitors + high-capacity tank-cooling monitors — 8-12 weeks lead time. Bulk volumes (10+ monitors for tier-1 refinery / petrochemical project) typically quoted on 12-16 week lead time with project-pricing terms.
Yes. Vasundhara is GeM-registered seller. HD Fire monitor nozzles available under standing rate contract for PSU buyers — IOCL, BPCL, HPCL, ONGC, GAIL, RCF, GSFC, NFL, Indian Oil + Hindustan Petroleum jetty + storage terminal operations, defence establishments. GFR-2017 compliant for deferred-payment supply. Documentation pack includes Udyam-MSME registration, manufacturer authorisation from HD Fire Protect, UL/FM/TAC/IS approval certificates.
Yes. Vasundhara Performance Solutions Pvt Ltd is the authorised HD Fire Protect fire-protection equipment distributor for Hyderabad, Telangana and Andhra Pradesh. We supply genuine HD Fire monitor nozzles with full manufacturer authorisation documentation provided on enquiry. For our complete HD Fire portfolio, see our HD Fire brand page.
Complete HD Fire portfolio supplied by Vasundhara — single-vendor sourcing for fire-protection EPC + factory safety teams.
Send us your requirement, pack size and quantity — quote returned within 4 hours during business hours.
Request Quote Call Now