Authorised Citel Surge Protection Distributor

Citel Replacement SPD Modules in Hyderabad — Cartridge Spares for Field-Serviceable SPDs

Vasundhara Performance Solutions is the authorised Hyderabad supplier for Citel replacement SPD modules — plug-in cartridge spares for Citel Type 1, Type 2, and Type 3 surge protective devices. After an SPD operates to end-of-life (status indicator window changes colour), the base unit stays mounted in the distribution board and only the spent module is swapped — no rewiring, no isolation procedure beyond a brief power-off. Restores surge protection in under 60 seconds per replacement. Pan-India dispatch from Secunderabad warehouse for plant maintenance + electrical contractor + facilities-management buyers.

Request Replacement Module Quote Call: +91-9912825442

Citel Replacement Module Range

Citel replacement modules cover all field-serviceable SPD families — Type 1, Type 2, Type 3, data-line, and solar PV variants.

DAC-25 / DAC-50 Type 1 Replacement Module

Plug-in replacement cartridge for Citel DAC-25 and DAC-50 Type 1 SPDs (Iimp 25 kA and 50 kA per pole). Operated module swap-out restores Type 1 lightning protection. Stock-and-replace model for plants with multiple Type 1 SPDs.

DS Type 2 Replacement Module

Plug-in replacement cartridge for Citel DS Type 2 SPDs (In 20-40 kA per pole). The most commonly replaced module across Indian industrial installations — Type 2 sees more frequent switching transients than Type 1. Stock 1-2 spares per installation.

DAS / DLU Type 3 Replacement Module

Plug-in replacement cartridge for DIN-rail (DAS) and plug-strip (DLU) Type 3 SPDs. Lower-amperage but more numerous — every PLC cabinet + server rack may have multiple Type 3 SPDs. Bulk stock for facilities with 50+ installed Type 3 SPDs.

DLA Data-Line Replacement Module

Plug-in replacement for Citel DLA Type 3 data-line SPDs (RJ45 Ethernet, RS-485, 4-20 mA, RJ11). Operates from data-line surge events — less frequent than power-line but critical for instrument loops + comms protection.

DUC / Combo Replacement Modules

Replacement modules for combination SPDs (Type 1+2, Type 1+2+3) — used where space constraints required combined Type SPD installations. Specialty supply on enquiry.

Citel SPD Spare-Parts Programme

For facilities with 100+ installed Citel SPDs, Vasundhara offers a spare-parts programme: pre-positioned spares at customer site + 24-hour replenishment + annual visual inspection of installed SPD indicators + replacement-scheduling guidance.

Technical Specifications

Standard property values across the range. TDS / MSDS / per-batch COA available on enquiry.

PropertyTest MethodDAC-25 ModuleDS Type 2 ModuleDAS Type 3 Module
Compatible Base SPDDAC-25 Type 1DS Type 2DAS Type 3
Iimp / In25 kA (10/350)20-40 kA (8/20)5 kA (8/20)
Uc — Continuous Voltage (V)275-440 V275-440 V275-320 V
Up — Protection Level (kV)≤ 2.5 kV≤ 1.5 kV≤ 1.0 kV
Module TypePlug-in cartridgePlug-in cartridgePlug-in cartridge
Replacement Time (per module)≤ 60 seconds≤ 60 seconds≤ 60 seconds
Status IndicatorWindow + remoteWindow + remoteWindow
Operating Temperature (°C)-40 to +85-40 to +85-40 to +85

Standards compliance: IEC 61643-11 SPD type specifications · CE marked + RoHS compliant · Field-replaceability per IEC 61643-12 maintenance guidance · Genuine Citel parts (no counterfeit) with traceable batch IDs

Application Areas by Industry

Where Citel replacement SPD modules ship from our Hyderabad warehouse — plant maintenance + facilities buyers.

Plant Maintenance + MRO Stock

Routine replacement module stock for plants with installed Citel Type 1/2/3 SPDs. Stock 10-20% of installed SPD count as spare modules — typical replacement rate is 5-15% per year depending on local lightning + switching transients. Auto-ancillary + process plants + manufacturing.

Electrical Contractor Stock

Electrical contractors supplying + maintaining commercial + industrial MEP installations stock Citel replacement modules to provide same-day SPD service to customer plants. Reduces customer downtime + supports contractor service-level commitments.

Facilities Management — IT + Building MEP

FM teams managing IT data centres + corporate buildings + hospitals stock Citel Type 3 replacement modules for PLC cabinets + server racks + critical-care equipment. Inventory-managed alongside other electrical spare parts.

Solar PV Maintenance

Solar PV O&M (operations & maintenance) contractors stock Citel Solar PV replacement modules — DC-side Type 1+2 + AC-side Type 2 SPDs at PV inverters. Higher replacement rate during monsoon-season lightning activity (June-September).

Telecom + Railway Signal

Citel replacement modules for telecom equipment + railway signal-system SPDs. Critical for 24/7 telecom + signal uptime. Stock-and-replace model standardised by Indian telecom + Railways procurement.

Post-Lightning-Event Service

Demand spike after major lightning events — plants need same-day or next-day module replacement. Vasundhara stocks Citel modules in Secunderabad for rapid dispatch across South India after lightning seasons.

Why Source Citel Replacement Modules from Vasundhara

Field-replaceable plug-in modules reduce SPD service cost + downtime vs full-unit replacement. Citel's modular design + genuine spare parts deliver predictable maintenance economics.

1. Authorised Citel Distribution

Genuine Citel France product through Citel India's official distribution channel. Manufacturer authorisation documentation provided on enquiry. Cartridge-traceability from manufacturer to installation site — critical for warranty claims after lightning events.

2. Same-Day Hyderabad Dispatch

Stocked SKUs ship same-day from Secunderabad warehouse. Less-common configurations typically 5-7 working days from Citel India stock or factory dispatch. Replacement cartridges stocked for service contracts.

3. SPD Coordination Engineering

Free SPD coordination calculations for projects where Vasundhara is the supply partner — Type 1 / Type 2 / Type 3 cascade design per IEC 61643-12, distance-rule verification, energy coordination check, fuse / MCB selection for SPD upstream protection.

4. GeM Rate Contract & Project Pricing

GeM-registered seller. Citel SPDs available under standing rate contract for PSU buyers. Project-pricing on bulk orders (50+ poles) for OEM panel-builders, EPC contractors, solar EPCs.

5. Single-Vendor Electrical Safety Kit

One PO for Citel replacement SPD modules + companion SPDs (Type 1, 2, 3) + downstream isolators + earthing accessories. Reduces vendor count for panel-builders sourcing the complete LV protection kit. See our Citel brand page.

6. Compliance Documentation Pack

Per-shipment test certificates (CE, IEC 61643-11 / IEC 61643-21 type-test), factory test reports, manufacturer authorisation letters from Citel France. Suitable for IEC 60364 / IS 732 panel-builder audits, MEP consultant submittals, EPC project documentation.

Pack Sizes & Bulk Supply

Standard packaging across the range. Bulk pricing on volumes >1,000 L.

Pack FormatVolumeTypical Use Case
Pail (HDPE)20 LSingle-machine top-up, sample-and-trial orders
Drum50 LMid-duty maintenance stock
Barrel (steel)210 LPlant maintenance stores standard
IBC Tote1000 L (1 MT)Bulk supply for high-volume users
Bulk Tanker3,000-5,000 L+Direct-to-tank delivery, large plants
📍

Visit Our Office: H.No. 10-2-309, Flat No. 201, Sudha Vaishnavi Residency, Street No. 4, West Marredpally, Secunderabad, Telangana 500026 | View on Google Maps

Frequently Asked Questions

Common questions from plant-maintenance + electrical-contractor buyers sourcing Citel replacement SPD modules through Vasundhara.

When should I replace a Citel SPD module?

Replace when the thermal-disconnect status indicator shows end-of-life: (1) window-style indicator changes from green to red; (2) remote-contact indicator triggers an alarm signal. Triggered by exceeded surge energy (operated SPD) or aged-out internal MOV (≥ 10-15 years). Visual check monthly + after every major lightning event in the area. Once end-of-life is indicated, the operated module no longer protects — schedule replacement within days, not weeks.

Can I replace a Citel SPD module without an electrician?

For DIN-rail SPDs (DAS, DS, DAC base units): replacement requires switching off the protected circuit briefly, removing the operated module by pulling/unlocking the cartridge, inserting the new module, and restoring power. Competent maintenance technicians can do this; full electrician licence not strictly required if isolation procedure is followed. For wall-mount + plug-strip SPDs (DLU): purely plug-in replacement, no electrical work.

How many spare Citel modules should I stock?

Recommended stock as % of installed SPD count: Type 1 SPDs — 5-10% spare stock (Type 1 operates rarely, only on major lightning events); Type 2 SPDs — 15-25% spare stock (most frequently replaced — switching transients hit Type 2 often); Type 3 SPDs — 10-15% spare stock (depending on local lightning activity). Solar PV SPDs — 20-30% spare stock (monsoon-season lightning concentration). Plus 1-2 spares per critical installation for same-day swap-out.

Are Citel replacement modules genuine vs counterfeit?

Vasundhara supplies only genuine Citel-branded replacement modules with traceable factory batch IDs. Counterfeit Citel modules sometimes appear in the Indian market — they often work briefly but fail prematurely or fail to operate on actual surge events, leaving equipment unprotected. Always source from authorised distributors. We provide certificate of genuineness + factory-batch traceability on every order.

Can I mix Citel modules across different installation dates?

Yes — Citel replacement modules of the same model number (e.g., DS Type 2 In 40 kA) are interchangeable regardless of manufacturing date. Stock can be rotated FIFO for inventory control. Verify the module's compatibility with the base SPD by checking the model number on the base unit before ordering replacement modules. Cross-check against the Citel compatibility matrix (provided with first order).

What's the shelf life of stocked Citel modules?

Citel SPD modules have indefinite shelf life when stored in original packaging at ambient indoor conditions (15-30°C, low humidity). MOV components don't degrade significantly during storage; capacitor components similarly stable. Long-term stocked modules should be visually inspected before installation for any damage during storage.

Do you supply Citel modules with annual rate contracts for plant MRO?

Yes. Vasundhara offers annual rate-contract supply for Citel replacement modules to plant maintenance + facilities management customers. Pre-agreed pricing + scheduled delivery + on-demand emergency dispatch after lightning events. Suitable for facilities with 50+ installed Citel SPDs across multiple locations.

Is Vasundhara the authorised Citel distributor for South India?

Yes. Vasundhara Performance Solutions Pvt Ltd is the authorised Citel Surge Protection distributor for Hyderabad, Telangana, Andhra Pradesh, Karnataka and South India. Full manufacturer authorisation documentation provided on enquiry. See our Citel brand page.

Related Citel Surge Protection Resources

Complete Citel SPD portfolio supplied by Vasundhara.

Citel Brand Page → Citel Type 1 SPDs → Citel Type 2 SPDs → Citel Type 3 SPDs → Citel Data-Line SPDs → Citel Solar PV SPDs →

Ready to Order Citel Replacement SPD Module?

Tell us your installed Citel SPD model numbers + quantity + monthly replacement rate. We'll respond with stock-and-replace programme pricing + annual rate-contract terms within one business day. Call +91-9912825442 or email [email protected] for same-day response.

Request Quote Call Now
Chat on WhatsApp