Vasundhara Performance Solutions is the authorised Hyderabad supplier for HD Fire booster pump sets — electric-driven and diesel-engine-driven fire pump systems per IS 12469 (Indian Boilers + fire-protection installation code). Single-stage + multi-stage horizontal split-case pumps + vertical-turbine pumps for high-rise + refinery + industrial installations. Sized from 450 lpm to 3000+ lpm at typical 7-10 bar discharge pressure. Pan-India dispatch + installation + commissioning + AMC across India.
Request HD Fire Booster Pump Quote Call: +91-9912825442Complete HD Fire booster pump portfolio — electric-driven + diesel-engine-driven + jockey pumps for the full range of Indian fire-protection installations.
Electric-motor-driven fire booster pumps per IS 12469. Single-stage + multi-stage horizontal split-case design. 450-3000+ lpm at 7-10 bar. The primary fire pump in most installations. Sized to deliver the maximum fire demand (typically 2-3 hydrants + sprinkler system simultaneously). Star-Delta starter + automatic-start panel.
Diesel-engine-driven backup fire pump per IS 12469 — mandatory backup to electric pump in PSU + critical installations. Engine size 25-200+ HP. Direct-coupled to pump via flexible coupling. Self-starting on pressure-drop detection. For refinery + power plant + hospital + high-rise installations where electric supply isn't guaranteed.
Small high-pressure pump for system-pressure maintenance — top-up after small leaks + diurnal pressure variations. Typically 25-75 lpm at 8-12 bar (higher pressure than main pump). Automatic-start on small pressure drop; main pump cuts in only on larger demand. See dedicated HD Fire Jockey Pumps page.
Vertical-turbine fire pumps for installations where pump is mounted above water source (overhead tank or open reservoir). Multi-stage impellers in vertical column. For high-rise installations + open-source water supply (river / canal / large reservoir).
Complete pump-set packages on skid + housed in pre-fabricated pump house. Includes electric pump + diesel pump + jockey pump + control panels + pressure tank + diesel fuel tank + battery + starter. Reduces on-site installation time from 30-60 days to 7-15 days.
Site survey, foundation specs, machine installation, electrical commissioning, performance test per IS 12469, AMC (preventive + breakdown response within 48 hours), genuine HD Fire spare parts (impellers, mechanical seals, starter motors).
Standard property values across the range. TDS / MSDS / per-batch COA available on enquiry.
| Property | Test Method | Electric 1500 lpm | Diesel 2280 lpm | Jockey 75 lpm |
|---|---|---|---|---|
| Flow Rate (lpm) | Field test | 1500 | 2280 | 75 |
| Discharge Pressure (bar) | Field test | 7-10 | 7-10 | 8-12 |
| Driver | — | AC Electric Motor | Diesel Engine | AC Electric Motor |
| Power Rating (HP) | — | 30-50 HP | 50-150 HP | 3-5 HP |
| Voltage | — | 415 V 3-phase | 12/24 V starter | 415 V 3-phase |
| Starting Method | — | Star-Delta | Self-starting on pressure | Automatic on pressure |
| Compliance | — | IS 12469 + NFPA 20 | IS 12469 + NFPA 20 | IS 12469 |
| Service Life (years) | — | 20-25 | 15-20 | 10-15 |
Standards compliance: IS 12469 (Indian Standard for fire-protection installation pumps) · NFPA 20 (Standard for Stationary Pumps for Fire Protection) · UL / FM Global listed where applicable · IBR compliance for steam-driven applications · OISD-RP-189 for refinery fire-protection installations
Where HD Fire booster pumps ship from our Hyderabad warehouse — by installation segment.
Electric + Diesel booster pumps for refinery main fire-pump houses. Critical 24/7 redundancy. IOCL, BPCL, HPCL, ONGC, Reliance refinery installations. Typically multiple electric pumps + multiple diesel pumps + jockey pump cascaded for maximum fire demand.
Electric + Diesel booster pumps for thermal + hydro + nuclear power plant fire-protection. NTPC, NLC, state Genco installations. Continuous-operation backup pumps for guaranteed fire-water supply.
Electric pump + jockey pump for high-rise commercial + hospital + IT building fire-protection. 15-50+ floors typical. Vertical-turbine pump for installations with rooftop tank + ground-level pump. Diesel backup for non-essential category-1 installations.
Booster pump sets for manufacturing + auto-ancillary + steel + cement plants. Sized per fire-protection design (typically 2 hydrants + sprinkler simultaneous demand). Cost-optimised vs refinery installations.
Electric + Diesel pumps for hospital fire-protection — government + private hospitals + medical-research installations. 24/7 reliability + IS 12469 compliance + Fire Safety Audit documentation.
Replacement of aged fire pumps + capacity upgrade for facilities scaling up. Includes capacity-revalidation study + foundation design + installation + commissioning + performance test.
HD Fire Protect is India's leading fire-pump manufacturer with 50+ years of industrial fire-protection experience. Their booster pump range delivers IS 12469 + NFPA 20 compliance at competitive Indian pricing with strong local service infrastructure.
Genuine HD Fire Protect equipment through manufacturer-authorised supply. UL / FM / TAC / IS approval documentation provided per shipment. Cartridge-traceability for warranty claims after service incidents.
Common-spec items stocked at Secunderabad warehouse for fast dispatch. Specialised configurations 1-2 weeks from HD Fire's Mumbai factory. Pan-India delivery to project sites under Vasundhara logistics control.
Hydraulic calculations, BOQ preparation, NFPA / IS compliance verification, design-document support for booster pump integration into the broader fire-protection system. Free for projects where Vasundhara is the supply partner.
One PO for HD Fire booster pump + companion equipment (hydrant valves, sprinklers, deluge valves, foam systems, monitors). Simplified procurement for EPC contractors and plant safety teams. See our HD Fire brand page.
Per-shipment test certificates, UL/FM/TAC type-test certificates, IS conformance reports, manufacturer authorisation letters. Suitable for fire department NOC submission, factory safety audit, MEP consultant submittals, and EPC project documentation.
GeM-registered seller — HD Fire equipment available under standing rate contract for PSU and Defence buyers. GFR-2017 compliant for deferred-payment supply. Documentation pack ready for streamlined Direct Procurement / L1 mode under GeM.
Standard packaging across the range. Bulk pricing on volumes >1,000 L.
| Pack Format | Volume | Typical Use Case |
|---|---|---|
| Pail (HDPE) | 20 L | Single-machine top-up, sample-and-trial orders |
| Drum | 50 L | Mid-duty maintenance stock |
| Barrel (steel) | 210 L | Plant maintenance stores standard |
| IBC Tote | 1000 L (1 MT) | Bulk supply for high-volume users |
| Bulk Tanker | 3,000-5,000 L+ | Direct-to-tank delivery, large plants |
Visit Our Office: H.No. 10-2-309, Flat No. 201, Sudha Vaishnavi Residency, Street No. 4, West Marredpally, Secunderabad, Telangana 500026 | View on Google Maps
Common questions from MEP consultants + project contractors + plant maintenance buyers sourcing HD Fire booster pumps through Vasundhara.
Per IS 12469 + NFPA 20, refinery + power plant + hospital + high-rise installations require redundant fire pumps to guarantee water supply during fire emergencies. The electric pump is primary (lower operating cost, faster start). The diesel-engine pump is backup — guaranteed to start even if electrical supply is interrupted (which is common during fire emergencies when power may be deliberately shut off). Both pumps sized for full fire demand. Plus a small jockey pump maintains system pressure during normal operation.
Pump capacity = maximum simultaneous fire demand. Typical calculation: (1) Number of fire hydrants likely to be used simultaneously (typically 2-3 per IS 13947); (2) Sprinkler system maximum design flow (per IS 15105); (3) Foam pourer or deluge demand if applicable; (4) Hose stream allowance. Sum these = required pump capacity. Plus safety margin (typically 10-15%). Discharge pressure = highest hydrant + friction losses + safety margin. Vasundhara coordinates capacity-sizing study with HD Fire technical team for our supply customers.
Yes — HD Fire pumps are functional equivalents at matched capacity + discharge pressure. Replacement typically straightforward: (1) capacity-revalidation study; (2) foundation check / re-engineering if needed; (3) electrical control-panel compatibility; (4) installation + commissioning. Pump-set replacement projects 30-60 days from PO to commissioning. Vasundhara coordinates end-to-end.
Three AMC tiers: (1) Basic AMC — annual preventive maintenance + minor parts replacement; (2) Comprehensive AMC — preventive + breakdown response within 48 hours + spare parts coverage; (3) Critical AMC — same-day breakdown response + full spare parts including impeller + mechanical seal + starter motor. AMC pricing 4-12% of pump value per year depending on tier.
Yes. Vasundhara is GeM-registered supplier. PSU tender response within 3-5 working days: HD Fire OEM authorisation letter, IS 12469 + NFPA 20 type-test certificates, capacity-test reports, AMC terms, installation + commissioning capability statement. PSU customers include IOCL, BPCL, HPCL, ONGC, NTPC, AAI, defence-PSU installations.
Standard electric pump sets: 12-16 weeks from PO confirmation. Diesel-engine pumps: 16-20 weeks (longer due to engine sourcing). Skid-mounted complete pump-set packages: 16-24 weeks. Installation + commissioning: 2-3 weeks after delivery. Total project: 14-26 weeks PO to first fire-pump test. Vasundhara coordinates everything end-to-end.
Both. Jockey pumps available as standalone supply for existing installations needing replacement or upgrade. Also bundled with main electric + diesel pumps in complete pump-set packages. See dedicated HD Fire Jockey Pumps page for jockey-pump-specific details.
Yes. Vasundhara Performance Solutions Pvt Ltd is the authorised HD Fire Protect distributor for Hyderabad, Telangana, Andhra Pradesh, Karnataka and South India. Full manufacturer authorisation documentation provided on enquiry. See our HD Fire brand page.
Complete HD Fire Protect portfolio supplied by Vasundhara.
Tell us your fire-protection design (refinery / commercial / industrial), required capacity (lpm) + discharge pressure (bar), site dimensions for pump house, and PSU tender requirements. We'll respond with rate-contract pricing + installation + AMC quote within one business day. Call +91-9912825442 or email [email protected] for same-day response.
Request Quote Call Now